1. 08 03-17

Additions, Revisions, or Updates

DiagnosticLink users: Please update the troubleshooting guides in DiagnosticLink with this newest version. To update the tool troubleshooting guide, open DiagnosticLink and from the Help – Troubleshooting Guides menu, select the appropriate troubleshooting manual, then click Update.

2. SPN 411/FMI 4 – GHG17

EGR Delta Pressure Sensor Circuit Failed Low

Table 1.

Check as follows:

1. Connect DiagnosticLink ®.

2. Turn the ignition ON (key ON, engine OFF).

3. Check for multiple fault codes. Is fault code SPN 3509/FMI 4 also present?
a. Yes; diagnose fault code SPN 3509/FMI 4.
b. No; Go to step 4.

4. Turn the ignition OFF.

5. Disconnect and inspect the EGR Delta P sensor electrical connector harness side. Is there any corrosion present?
a. Yes; replace the EGR Delta P sensor and the electrical connector. Refer to section “Removal of the Delta P
Sensor”. Verify repair.
b. No; Go to step 6.

6. Is the connector or any of the pins damaged?
a. Yes; Go to step 7.
b. No; Go to step 8.

7. Inspect the EGR Delta P sensor electrical connector component side, is the connector or are any of the pins damaged?
a. Yes; replace the EGR Delta P sensor and the electrical connector. Refer to section “Removal of the Delta P
Sensor”. Verify repair.
b. No; replace the EGR Delta P sensor electrical connector.

8. Turn the ignition ON (key ON, engine OFF).

9. Measure the voltage between pin 1 and pin 2 of the EGR Delta P sensor electrical connector harness side. Is the
voltage between 4.5 and 5.5 volts?
a. Yes. Go to step 11.
b. No; Go to step 10.

10. Measure the voltage between pin 1 and ground. Is the voltage between 4.5 and 5.5 volts?
a. Yes; repair the circuit between pin 1 of the EGR Delta P sensor electrical connector harness side and the splice.
Verify repair.
b. No; repair the circuit between pin 2 of the EGR Delta P sensor electrical connector harness side and the splice.
Verify repair.

11. Use the appropriate flex probes to jump pin 1 and pin 3 of the EGR Delta P sensor electrical connector harness side together.

12. Check the fault codes, does fault code SPN 411 FMI 4 become inactive and fault code SPN 411/FMI 3 become active?
a. Yes; replace the EGR Delta P sensor. Refer to section “Removal of the Delta P Sensor”. Verify repair.
b. No; repair the circuit between pin 3 of the EGR Delta P sensor electrical connector harness side and pin 109 of
the 120-pin MCM electrical connector harness side.

 

Reviews

There are no reviews yet.

Be the first to review “SPN 411 (MCM) (GHG17)”

Your email address will not be published. Required fields are marked *

The names Cat, Caterpillar, Detroit or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
gdsdieselparts.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.
gdsdieselparts.com ©2019- 2024

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
X